60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control

Guangdong Jiesheng Electric Technology Co., Ltd
Contact Now
    Buy cheap 60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control from wholesalers
     
    Buy cheap 60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control from wholesalers
    • Buy cheap 60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control from wholesalers
    • Buy cheap 60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control from wholesalers

    60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control

    Ask Lasest Price
    Brand Name : STABLECU
    Model Number : ST310-4T30G-37G
    Certification : CE
    Price :
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability :
    Delivery Time : 5-8 days
    • Product Details
    • Company Profile

    60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control

    60HZ To 50HZ Converter 37KW 30KW Adjustable Speed AC Motor Control


    Introduction of variable frequency drive

    1. Choose first-tier suppliers in the industry for capacitors, fans, electronic components, PCB boards, etc., to ensure the health and stability of the product throughout its life cycle. Using imported Infineon IGBT,
    2. The operation is simple and convenient.
    3. Built-in RS485 interface. And supports Modbus communication protocol.
    4. Strong overload capacity, 150% rated current for 60 seconds, 180% rated current for 10 seconds; 200% rated current for 0.54 seconds.
    5. The four fault records can effectively record the maximum current, maximum voltage, and maximum temperature of the last four times, which is helpful for customers to analyze and deal with faults and improve after-sales efficiency.

    Instructions for peripheral devices of variable frequency drive

    NameInstruction
    The power supplyThe input 3-phase AC power supply shall meet the scope specified in this manual
    The circuit breaker

    Purpose: It can cut off the power supply and protect the after-stage when the after-stage equipment has abnormal over-current.

    Selection: the breaking current of the circuit breaker is selected as 1.5 ~ 2 times of the rated current of the frequency converter. The time characteristics of the circuit breaker should be selected according to the time characteristics of the overload protection of the frequency converter.

    Leakage protector

    Purpose: Because the output of the frequency converter is PWM high-frequency chopper voltage, so the high-frequency leakage current is unavoidable.

    Selection: B type special leakage protector is recommended.

    Contactor

    In order to ensure safety, please do not close and disconnect the contactor frequently, which will cause frequency converter breakdown.

    Do not control the start and stop of the frequency converter by closing and disconnecting the contactor to the system, which will reduce the life of the frequency converter.

    Input AC reactor or DC reactorImprove power factor and the influence of three-phase input AC power imbalance on the system to suppress high harmonics. Reduce the external conduction and radiation interference, and effectively suppress the influence of pulse current on the rectifier bridge.
    Input filter

    Reduce the conduction interference from the power supply end to the frequency converter, and improve the frequency converter's anti-interference ability.

    Reduce the external conduction and radiation interference of the frequency converter.

    braking unit and braking resistor

    Purpose: When braking, it can effectively consume the energy of motor feedback and realize fast braking.

    Selection: Refer to recommended resistance and power for selection of braking resistors.

    Output filterReduce the external conduction and radiation interference of the frequency converter
    Output AC reactor

    Effectively avoid damage to motor insulation due to harmonic voltage and reduce the frequency converter frequent protection due to leakage current

    When the connection between the frequency converter and the motor exceeds 100 meters, it is recommended to mount an output AC reactor

    MotorSelect the motor matching with the frequency converter

    Product details of variable frequency drive

    60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control

    60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control

    60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control

    FAQ

    1. Who are we?
    We are a manufacturer based in Guangdong, China, starting in 2009, selling to Domestic Market(100.00%).
    There are a total of about 201-300 people in our office.
    2. How can we guarantee quality?
    Always a pre-production sample before mass production; Always final Inspection before shipment.
    3. What can you buy from us?
    Ultrasonic Generator, PLC/Motion Controller, Servo Motor And Stepper Motor, Frequency Converter,
    Automation System Development And Complete Set Of Electric Box.
    4. Do you offer customization services?
    Yes, we can customize the products according to your requirements. Please send us an inquiry, your inquiry
    will be replied within 12 hours.
    5. What services can we provide?
    Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDP, DDU, Express Delivery;
    Accepted Payment Currency: USD, EUR, JPY, CAD, AUD, HKD, CNY;
    Accepted Payment Type: T/T, L/C, D/P D/A, MoneyGram, Credit Card, PayPal, Western Union, Cash;
    Language Spoken: English, Chinese.

    Quality 60HZ To 50HZ Heavy Duty Inverter , Variable Speed Drive Inverter AC Motor Control for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Jiesheng Electric Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)